Do I Need a New Hot Water Cylinder for an Air Source Heat Pump?

If you are installing an air source heat pump, you will usually need a suitable hot water cylinder, and your existing cylinder may need to be replaced. Heat pumps do not normally provide hot water instantly in the same way as a combi boiler, so hot water is typically heated and stored ready for your taps, showers and baths.

That does not mean every heat pump installation automatically needs a brand-new cylinder. An installer should assess what you already have, how much hot water your household uses and whether the existing cylinder is suitable for the proposed heat pump. In this guide, we explain:

  1. Why heat pumps normally use hot water cylinders
  2. What happens if you currently have a combi boiler
  3. Whether an existing cylinder can be reused
  4. Why heat pump cylinders can be different
  5. How the correct cylinder size is calculated
  6. What happens if the cylinder is too small or too large
  7. How long hot water takes to recover
  8. Why cylinder location matters
  9. How immersion heaters fit into the system
  10. What an installer should check before designing your system

Why does an air source heat pump need a hot water cylinder?

A standard air-to-water heat pump supplies heat to your central heating system and can also heat your domestic hot water.

Unlike a typical combi boiler, however, it does not usually produce large quantities of hot water instantly when you open a tap.

Instead, the heat pump gradually heats water stored inside a cylinder. That stored hot water is then available when you need a shower, bath or hot tap.

This means hot water storage needs to be considered as part of the complete heat pump design rather than added as an afterthought.


What happens if you currently have a combi boiler?

If your home currently uses a combi boiler, you may not have a hot water cylinder at all.

A combi heats mains water as you use it, which is why many homes converted to combi boilers had their old cylinders removed.

Moving from a combi boiler to a standard air-to-water heat pump will therefore usually mean introducing some form of hot water storage.

For homeowners in Horley, Reigate, Redhill and Crawley, one of the important parts of a heat pump survey is identifying where that equipment could realistically go.

An airing cupboard, utility room or another suitable internal area may be considered depending on the property and system design.


Can you keep your existing hot water cylinder?

Possibly, but it should never be assumed.

If you already have a system or regular boiler with a hot water cylinder, an installer should assess the existing cylinder before deciding whether it can remain.

Factors can include:

  • the type of cylinder
  • its age and condition
  • its storage capacity
  • the size and design of its heat exchanger coil
  • the required hot water temperature
  • the proposed heat pump
  • your household’s hot water demand

Energy Saving Trust advises that an existing cylinder will probably need replacing with one suitable for a heat pump. The final decision, however, should be based on the actual equipment and system design rather than a blanket rule.


Why can a heat pump need a different type of cylinder?

The way heat is transferred into the stored water matters.

Inside an indirect hot water cylinder is a heat exchanger, commonly a coil, through which heated water from the heating system circulates.

A heat pump generally operates differently from a conventional boiler and often uses lower water temperatures during normal operation.

A cylinder designed to work effectively with a heat pump can use a suitably sized heat exchanger to transfer heat into the stored water efficiently.

An older cylinder designed around a traditional boiler may not necessarily be appropriate for the new system.

This is why simply connecting a heat pump to whatever cylinder is already in the airing cupboard may compromise performance.


What size hot water cylinder do you need with a heat pump?

The correct cylinder size depends primarily on your household’s hot water requirements rather than the floor area of the house.

An installer may consider:

  • how many people live at the property
  • the number of bathrooms
  • whether you mainly use showers or baths
  • how much hot water is typically used
  • peak periods of hot water demand
  • available space for the cylinder
  • the heat pump and cylinder recovery performance

A five-bedroom house occupied by two people could have a very different hot water requirement from a smaller home occupied by a large family.

That is why cylinder sizing should be based on actual demand rather than choosing the biggest cylinder that will physically fit.


Is a bigger hot water cylinder always better?

No.

A cylinder needs enough capacity to provide the household with appropriate hot water, but unnecessarily oversizing it is not automatically beneficial.

A larger cylinder takes up more space and stores a greater volume of heated water. The system therefore needs to be designed around a sensible balance between capacity, recovery and household demand.

An undersized cylinder can be equally problematic because occupants may run out of stored hot water during periods of high demand.

The objective is not simply to maximise litres. It is to provide the amount of usable hot water the property actually requires.


Will a heat pump give you enough hot water for showers and baths?

Yes, when the hot water system is correctly designed.

A heat pump can provide domestic hot water for normal household use, including showers, baths and taps.

The important difference is that you are using stored hot water rather than expecting the system to heat an unlimited amount instantly.

The installer therefore needs to consider both how much hot water you use and how quickly the system can replenish it.

A properly designed system should make this largely unnoticeable during everyday use.

If a household has unusually high hot water demand, that should be discussed during the survey rather than discovered after installation.


What does hot water recovery time mean?

Recovery time is how long the system takes to reheat the cylinder after stored hot water has been used.

Imagine several people showering one after another in the morning. The cylinder is supplying stored hot water while the system subsequently needs to replace that heat.

The recovery time depends on factors including the cylinder, heat exchanger, heat pump output, water temperatures and controls.

This is another reason why cylinder capacity alone does not tell you whether a system is suitable.

A professional design considers how the heat pump and cylinder work together.


How hot does a heat pump make the water?

The domestic hot water temperature depends on the heat pump, cylinder, controls and system settings.

Heat pumps are generally most efficient when they do not have to produce unnecessarily high water temperatures. Domestic hot water, however, has different requirements from normal space heating.

The system therefore needs appropriate controls and a strategy for maintaining safe stored-water conditions.

Many systems can also use an immersion heater as part of their hot water arrangement when required.

The exact temperatures and control strategy should be set by the installer for the particular system rather than copied from another property.


What does the immersion heater do?

A heat pump-compatible cylinder will commonly include an electric immersion heater.

An immersion heater is an electrical heating element fitted directly into the cylinder. It heats the stored water using electrical resistance rather than the heat pump’s refrigeration cycle.

Depending on the system design, it can be used for functions such as supplementary heating or periodic high-temperature hot water cycles.

It should not normally be confused with the main heat pump itself.

The installer should configure the controls correctly and explain how the hot water and immersion functions operate during handover.


Where can the hot water cylinder go?

Location can be one of the biggest practical considerations, particularly when converting a home that currently has a combi boiler.

A suitable cylinder needs physical space as well as appropriate access for installation, pipework and future maintenance.

Depending on the property, potential locations may include an existing airing cupboard, utility room or another suitable service area.

The cylinder is only one part of the arrangement. The installer also needs to consider pipe routes, controls, valves and other system components.

For smaller properties across Surrey and West Sussex, space should therefore be assessed early in the design process.


What if you do not have space for a conventional cylinder?

Limited space does not necessarily rule out a heat pump, but it can affect the available system options.

Energy Saving Trust notes that alternative hot water storage solutions can sometimes be considered where a conventional cylinder cannot reasonably be accommodated.

The suitability of these alternatives depends on the property, heating design and household hot water requirements.

This is an area where generic online advice can be misleading. A solution that works well in one small property may not provide enough hot water in another.

A survey allows the installer to consider both the physical space and the expected demand before recommending equipment.


Should you replace the cylinder before getting a heat pump?

Usually, it makes more sense to have the complete heat pump system designed first.

Buying a cylinder independently before the heat pump has been specified can leave you with equipment that is the wrong size or unsuitable for the eventual design.

The cylinder, heat pump, radiators, pipework and controls all form part of the same heating and hot water system.

If your existing cylinder is approaching the end of its life and you are already considering a heat pump, tell your installer before replacing it.

They can then advise whether it is sensible to coordinate the work rather than paying for equipment that may later need changing again.


What should an installer check before choosing your cylinder?

A proper heat pump survey should look at your hot water requirements alongside the building’s heating requirements.

JPEC Green Energy would typically need to understand factors such as your existing heating system, current cylinder, number of occupants, bathrooms, hot water habits, available space and proposed heat pump design.

The installer should also assess the wider system, including:

  • property heat loss
  • heat pump output
  • radiator or underfloor heating requirements
  • required flow temperatures
  • existing pipework
  • electrical supply
  • heating and hot water controls
  • location of the outdoor unit

This complete-system approach is much more reliable than selecting the heat pump and cylinder separately.


JPEC Green Energy can help

If you are considering an air source heat pump, JPEC Green Energy can survey your property and design the heating and hot water system around how your home is actually used.

We install air source heat pumps across Horley, Reigate, Redhill, Crawley, Surrey and West Sussex and can assess your existing boiler, hot water cylinder, radiators, pipework, electrical supply and household hot water demand.

If your existing cylinder is suitable, that can be considered during the design. If a replacement is required, the proposed cylinder should be selected as part of the complete heat pump system rather than as a separate guess.

JPEC Green Energy can take the project from survey and heat-loss calculations through system design, installation, commissioning and handover, explaining how the heating and hot water controls work once the system is running.

To arrange a heat pump survey and receive a quotation based on your property, contact JPEC Green Energy.

This article provides general information and is not personal heating, plumbing or technical advice. Hot water storage requirements, cylinder sizing and compatibility depend on the property, existing system, household demand and proposed heat pump. Recommendations should be confirmed through a professional survey and system design.

Get in touch

Get in touch and talk to our helpful, friendly team. Take the first step towards lower energy bills and green energy solutions with JPEC Green Energy.